M201

Precision High Voltage Capacitance Bridge

Precision High Voltage Capacitance Bridge M201 measures the capacitance and dissipation factor (tanδ) with high accuracy

Measuring using M201 requires the use of the external high voltage standard capacitor

Maximum test voltage is limited higest voltage value of standard capacitor

FEATURES AND BENEFITS

  • High measurement accuracy C&tanδ testing: up to ± 0,002 % (Cx) and ± 0,00002 (tanδ)
  • Measurement of C&tanδ at test current up to 50 A
  • Easy handling
  • Small size and low weight

APPLICATIONS

M201 is used for:

  • Precision C&tanδ measurement of standard capacitors
  • Precision C&tanδ measurement of capacitors and HV cables with large capacitance
  • C&tanδ testing on rated voltage of: Instrument Transformers, Power Transformers, Bushings, Switches, Surge Arresters, Capacitors, Cables
  • Metrological research

TEST ARRANGEMENT

The circuit for measurements of capacitance less than 1 μF (test current up to 0,5 A)

The circuit for measurements of capacitance more than 1 μF (test current up to 50 A)

Measurement ranges and error limits of M201 without error limits of the standard capacitor

# subr

СХ0Allowable current  flowing through the measurement object circuit , АLimits of relative error for the capacitance measurement, %

Limits of absolute error for the dissipation factor measurement

10,01…0,10…0,5±[2×10-3 +2×10-4×(C0/CX  -10) +|tanδX – tanδ0|]

±[2×10-5 + 2×10-6×(C0/CX  -10) +

0,005×|tanδX – tanδ0|]

0,1…1,0±[1×10-3 + |tanδX – tanδ0|]±[1×10-5 + 0,005×|tanδX – tanδ0|]
21,0…10
310…102
4102…103±[2×10-3 + |tanδX – tanδ0|]±[2×10-5 + 0,005×|tanδX – tanδ0|]
5*103…104 0,03…5±[5×10-3 + |tanδX – tanδ0|]±[5×10-5 + 0,005×|tanδX – tanδ0|]
6*104…1050,3…50

* – with M200E1 using

Measurement ranges and error limits of M201 with the standard capacitor using. Capacitor is the part of M201

# subr

СХ0Allowable current  flowing through the measurement object circuit , АLimits of relative error for the capacitance measurement, %

Limits of absolute error for the dissipation factor measurement

10,01…0,10…0,5±[5×10-3 +2×10-4×(C0/CX  -10) +|tanδX – tanδ0|]

±[5×10-5 + 2×10-6×(C0/CX  -10) +

0,005×|tanδX – tanδ0|]

0,1…1,0±[4×10-3 + |tanδX – tanδ0|]±[4×10-5 + 0,005×|tanδX – tanδ0|]
21,0…10
310…102
4102…103±[5×10-3 + |tanδX – tanδ0|]±[5×10-5 + 0,005×|tanδX – tanδ0|]
5*103…104 0,03…5±[8×10-3 + |tanδX – tanδ0|]±[8×10-5 + 0,005×|tanδX – tanδ0|]
6*104…1050,3…50

* – with M200E1 using

Limits of relative error for the testing voltage measuremen±1 %
Limits of absolute error for the testing voltage frequency measurement±0,1 Hz
Power mains:
     Measuring unitbuilt-in rechargeable battery
     Charging unit:
     Rated Voltage220/230 V
     Rated Frequency50 Hz
Normal conditions:
     Temperature range15°С … 25°С
     Relative HumidityUp to 80 %. non-condensing
Operating Temperature0 … 40 °С
Relative HumidityUp to 80 % non-condensing
Size:
     M201250 x 185 x 350 mm
     M200E1130 x 200 x 200 mm
Weight:
     M20110 kg
     M200E14 kg
Standards compliance:

Safety

EMC


Calibration Interval 

 

IEC 61010-1:2010

IEC 61326-1:2013


2 years recommended

* – measuring at the frequency of 60 Hz can be agreed with the customer