M500

Programmable Standard Current Transformer

Programmable Standard Current Transformer М500 and Range Extender М500E1 provides unique abilities of current ratio control in automated CT calibration systems

M500 high accuracy is achieved by using a two-stage technology and electronic compensation of burden influence

    FEATURES AND BENEFITS

    • High accuracy (current error ± 0,005 %; phase displacement ± 0,15 min)
    • Rated primary current range: 0,5 … 5000 А
    • Rated secondary current: 5 А
    • Primary current values are selected using the control knob rotary encoder or by PC via the USB interface
    • Electronic burden compensation of secondary circuits
    • Possibility of using with automated CT calibration systems
    • Built-in overload protection
    • Small size and low weight

    APPLICATIONS

    M500 is used by:

    • Manufacturers of Current Transformers
    • On-site testing of Current Transformers
    • Calibration Laboratories
    • Metrology Institutes

    Version

    M500.1

    M500.2

    M500.3

    Current range, %

    1…120

    1…150

    1…150

    M500
    Rated primary
    current, A
    0,5; 1; 1,5; 2; 2,5; 3; 4; 5; 7,5; 10; 15; 20; 25; 30; 40; 50; 60; 75; 80; 100; 125; 150; 200; 250; 300; 400; 500; 6000,5; 1; 1,25; 1,5; 2; 2,5; 3; 4; 5; 6; 7,5; 10; 12,5; 15; 20; 25; 30; 40; 50; 60; 75; 80; 100; 125; 135; 150; 175; 200; 250; 300; 350; 400; 500; 6000,5; 0,6; 0,7; 0,75; 0,8; 0,9; 1; 1,25; 1,5; 2; 2,5; 3; 3,5; 4; 4,5; 5; 5,5; 6; 6,5; 7; 7,5; 8; 8,5; 9; 9,5; 10; 12,5; 15; 20; 25; 30; 35; 40; 45; 50; 55; 60; 65; 70; 75; 80; 85; 90; 95; 100; 105; 110; 115; 120; 125; 130; 135; 140; 145; 150; 155; 160; 165; 170; 175; 180; 185; 190; 195; 200; 225; 250; 275; 300; 325; 350; 375; 400; 425; 450; 475; 500; 525; 550; 575; 600
    M500E1
    Rated primary
    current, A
    750; 800; 1000; 1200; 1250; 1500; 1600; 2000; 2400; 2500; 3000; 4000; 5000*750; 800; 1000; 1200; 1250; 1500; 1600; 1800; 2000; 2400; 2500; 3000; 3200; 3500; 4000; 5000*650; 700; 750; 800; 850; 900; 950; 1000; 1050; 1100; 1150; 1200; 1250; 1300; 1350; 1400; 1450; 1500; 1550; 1600; 1650; 1700; 1750; 1800; 1850; 1900; 1950; 2000; 2100; 2200; 2250; 2300; 2400; 2500; 2600; 2700; 2750; 2800; 2900; 3000; 3100; 3200; 3300; 3400; 3500; 3600; 3700; 3800; 3900; 4000; 4100*; 4200*; 4300*; 4400*; 4500*; 4600*; 4700*; 4800*; 4900*; 5000*
    Rated secondary
    current, A

    5

    Burden power, V·A

    ≤ 5

    Current error, %

    ±0,005

    Phase
    displacement, min

    ±0,15

    * Values are possible for 1 to 120 % of rated current
    Power mains
    Rated voltage
    Rated frequency

    220/230 V
    50 Hz
    Operating temperature0...40 °C
    Relative humidityup to 80 % non-condensing
    Size
    M500
    M500E1

    546 × 347 × 247 mm
    110 × 350 × 210 mm
    Weight
    M500
    M500E1

    17 kg
    7 kg
    Standards
    Safety
    EMC
    EN 61010-1:2010
    EN 61326-1:2013
    Calibration Interval5 years recommended